Molykote 1000 tube 100ml lead and nickel free anti-seize paste-grease
Description
Molykote 1000
Molykote 1000 is a high-load bearing lubricant paste designed specifically for metal/metal bolting applications, particularly where high temperatures and corrosion occur. This product enables easy disassembly after long-term use even under extreme conditions, while providing excellent protection against wear and corrosion.
Application
- First lubrication and protection of bolted connections exposed to high temperatures up to 650°C
- Ideal for cylinder head bolts, plastic injection molding machine injectors and bolted connections in the chemical industry
- Used in centrifuge tension rings and other highly loaded mechanical elements
Properties
- High temperature resistance (up to 650°C)
- High load capacity and wear protection
- Enables non-destructive disassembly after long periods of use
- Constant friction coefficient, even after repeated tightening and loosening of screws
- Excellent corrosion protection
- Free from lead, nickel, PTFE and PFAS
Technical parameters
Parameter | Value |
---|---|
Colour | Brown |
Non-working penetration (ISO 2137) | 280-310 mm/10 |
Density at 20°C (ISO 2811) | 1.26 g/ml |
Operating temperature range | -30°C to +650°C |
Weld load (DIN 51 350 part 4) | 4800 N |
Wear scar diameter at 400 N load (DIN 51 350 part 5) | 0.65 mm |
OK Load (Almen-Wieland) | 20,000 N |
Friction force (Almen-Wieland) | 2600 N |
Friction coefficient (screw test - µ thread) | 0.13 |
Friction coefficient (screw test - µ head) | 0.08 |
Initial breakaway torque | 135 Nm |
Storage and use recommendations
- Store in original sealed containers at temperatures below 20°C
- Shelf life is 60 months from the date of production
- Before application, clean threads and screws thoroughly, preferably using a wire brush
- Do not mix the paste with other greases or oils, so as not to change its properties
Safety
Before using the product, read the Safety Data Sheet (MSDS). The product should be used in accordance with the manufacturer's recommendations and occupational health and safety regulations. During application, use appropriate personal protective equipment to avoid contact with eyes and skin.